Cleveland-range KEL-25 User Manual

Browse online or download User Manual for Kitchen Cleveland-range KEL-25. Cleveland Range KEL-25 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Cleveland
P
roject ________________________________
I
tem __________________________________
Quantity _______________________________
F
CSI Section ____________________________
A
pproval _______________________________
Date __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
ELECTRIC KETTLES
Cleveland Standard Features
n
Self-contained, easily installed - needs only an electrical hook-up
n Steam jacket filled with treated water
, venting and/or refilling is
not required
n Accurate, consistant solid state temperature controls (mechani-
cal thermostate not as accurate) - less than ±1°C variance
(ideal for simmering). Operating temperature range from 145° -
260°F (63°C - 127°C)
Control panel includes:
LED indicator for heat cycle • LED indicator for low water
Power ON/OFF switch • Adjustable temperature control dial
n Water resistant controls, splash-proof construction
n Re-inforced rolled rim design prevents damage to kettle rim,
eliminates "bar rim designs"
n Welded-in heating elements, (holds vacuum better
, won't leak
or loose water)
n Easily cleaned: kettle and all exterior surfaces are of type 304
stainless steel with an #4 finish
n Rear mounted easy access pressure gauge and pressure relief
valve to prevent tampering. Color coded easy to read pressure
gauge with "green" and "vent air zone"
n 50 psi steam jacket rating for higher cooking temperatures
n 50 psi safety valve
n
Solid state water level control (no sight glass gauge to break or leak)
n Splash proof element cover with a double gasket seal
n Faucet mounting bracket
n 2˝ diameter tangent draw-off valve with drain strainer
n
1 5/8˝ O.D. tri-leg supports with level adjustable feet for floor bolt-
ing
n Spring-assisted, hinged, rotatable, domed stainless steel cover
n Standard voltage is 208-240 volts, 60 Hz, 3-phase, 3-wire
n T
ypical approvals include UL., CSA, CE, NSF and ASME
Options & Accessories
p Hot and Cold W
ater Faucet with Swing Spout (DPK)
p T
ype 316 Stainless Steel Kettle Liner for high acid food
products (316)
p Cooking Baskets and
T
ri-Basket Supports (BS and
TBS)
p Kettle
Accessory Kit (KAK) includes:
p Clean-up Brush (CB) p 36˝ Kettle Paddle (KP)
p 36˝ Kettle Whip (KW) p 36˝ Kettle Brush (KB)
p Draw-of
f Brush (DB)
p 24 oz. Ladle (KL)
p Automatic W
ater Meter (GMF or LMF)
p W
ater Meter Stand (SWM)
p Lift-of
f Covers (CL)
p Drain Strainers (DS-)
p Measuring Strip
(MS)
Shall be CLEVELAND, Electric Kettle, T
ri-leg mounted, self-con-
tained, stationary, Model KEL - _____ gallons, 2⁄3 Steam Jacketed.
Type 304 Stainless Steel Kettle and Supports. Rated 50 psi with
Safety Valve; Permanently filled Steam Jacket. Spring-assisted
Domed Cover. (Provide 1.50˝ Freeboard above batches of rated
size.) Splash Proof Solid State Temperature
(±1° C) and Safety
Control System in plug-in Module including L.E.D. indicators. Base
Mounted for Floor Bolting with thr
ee (3), tri-bolt flanges. 2˝ diameter
T
angent Draw-of
f V
alve.
p Kettle Markings (KM)
p Hot and cold or cold only Kettle Filler with 60˝ Hose
(DKF-K or SKF-K)
p Swing Funnels for drain (SF)
p Alternate Mounting Systems
p High Wattages and Special Voltages
p 3" diameter Tangent Draw-Off Valve w/Strainer (TD3)
p Heat Deflector Shield (HS001)
p Correctional Packages
p Insulated Outer Jacket (IOJ)
Shor
t Form Specifications
SECT. VIII PAGE 13
0707
TRI-LEG, ELECTRIC KETTLES
STATIONARY, “
SPLASH PROOF SERIES”
, SELF-CONTAINED
2⁄3 STEAM JACKETED
,
25, 40, 60, 80 or 100 GALLONS
(100, 150, 225, 300, or 375 LITERS)
MODELS: c KEL-25 c KEL-60
c KEL-30 c KEL-80
c KEL-40 c KEL-100
Page view 0
1 2

Summary of Contents

Page 1 - Cleveland

Cleveland™Project ________________________________Item __________________________________Quantity _______________________________ FCSI Section ___

Page 2 - DIMENSIONS

RECOMMENDEDFLOOR SLOPE1" (26 mm) per 4' (1220 mm)PIPE DRAIN RECOMMENDEDmin. valve size plus 1" (26 mm)4" (102 mm)RECOMMENDED9/16&q

Related models: KEL-30