Service & Parts Manual
Convotherm Combination Oven-Steamer
MODELS:
Gas 20.20
OGB-20.20OGS-20.20
0706
1333 East 179th St., Cleveland, Ohio, U.S.A. 441
10
Phone: (216) 481-4900 Fax: (216) 481-3782
Visit our web site at www.clevelandrange.com
Enodis
by
Page view 0
1 2 3 4 5 6 ... 80 81

Summary of Contents

Page 1 - Service & Parts Manual

Service & Parts ManualConvotherm Combination Oven-Steamer MODELS: Gas 20.20OGB-20.20OGS-20.2007061333 East 179th St., Cleveland, Ohio, U.S.A. 4411

Page 2 - Table of Contents

NOTES:Cleveland Range reserves right of design improvement or modification, as warranted.Many regional, state and local codes exist and it is the resp

Page 3 - FOR THE INSTALLER

1333 East 179th St., Cleveland, Ohio, U.S.A. 44110Ph: 1-216-481-4900 Fx: 1-216-481-3782 Web Site: www.clevelandrange.comCleveland Range, LLCS

Page 4

NOTES:Cleveland Range reserves right of design improvement or modification, as warranted.Many regional, state and local codes exist and it is the resp

Page 5

Figure 4-1a Control Panel CONTROL PANEL BASIC OPERATION A. QUICK START GUIDE ALWAYS PRE-HEAT THE OVEN CHAMBER! 1. Switch on with key (1). 2. Se

Page 6 - INSTALLATION INSTRUCTIONS

Figure 4-1b Control Panel B. CONTROL PANEL DETAIL VIEW Note: Item numbers correspond to numbers on the control panels in Figure 4-1b 1. ON/OFF When

Page 7

Function Indicators • Light up when function or activity is engaged: 10. Reduced Power 11. Burner or Electric Heating ON 12. Reduced Fan Speed 13. Coo

Page 8

CAUTION Clean the oven chamber at least once per day or more frequently as needed Failure to clean the Combi properly and regularly can cause equipmen

Page 9

CAUTION Do NOT use U-Shaped racks that are bent or otherwise damaged in any way. Pans and accessories placed in damaged racks can tip and spill, causi

Page 10 - OGS 20.20

Drain Cover and Drain e. Clean the Bypass Measuring Aperture. (Opening in the oven chamber on the left-hand side, slightly below the door latch. See

Page 11 - Cleveland Range

B. Semi-Automatic Cleaning of the Oven Chamber NOTE: Do NOT press the Start/Stop key while using the Semi-automatic Cleaning process. This stops the

Page 12

Table of ContentsInstallation For the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Warranty .

Page 13 - BASIC OPERATION

a. The third step is Steam mode at 86°F for 1 minute. No action is needed. b. The fourth step is Steam at 212°F for 10 minutes, followed by a Signal

Page 14 - B. CONTROL PANEL DETAIL VIEW

CAUTION Always make sure the cleaning agent containers are correctly connected to the Combi CONVOClean => RED CONVOCare => BLUE or WHITE C. CON

Page 15 - Settings

3 “Strong Soiling” 2 hours. 4 ‘Strong Soiling – Shining+” 2 hours and 45 minutes. 8. Press the Smart Key. 9. “Food inside oven?” appears in t

Page 16 - CAUTION

CAUTION Use ONLY the DISSOLVE® Descaler method using Part No. 106174 to descale the Combi. Read, understand, and follow both the descaling procedure i

Page 17

WARNING This procedure is slightly different depending on the model being descaled. This entire procedure should be read and fully understand as it a

Page 18

• While adding liquid to the steam generator through the descaler inlets, pour slowly to avoid overflow. • Wipe up any spills at once to avoid etching

Page 19

C3216313 B0706CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVE

Page 20

C3216313 B0706IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2114828 ASSEMBLY/WELDMENT, TOP, INTERMEDIATE, 12.20/20.20 2 1 C2115487 ASS

Page 21

C3216313 B0706CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVE

Page 22

C3216313 B0706IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2114828 ASSEMBLY/WELDMENT, TOP, INTERMEDIATE, 12.20/20.202 1 C2115487 ASSE

Page 23 - DESCALE STEAM GENERATOR

NOTICEPost instructions to be followed if the user smells gas. Display the instructions in a prominent location. All users of this equipment must unde

Page 24

300504 A0706COMPONENT PANEL ASSEMBLY, GASOGB 20.20 MODELSCLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A PR

Page 25

300504 A0706COMPONENT PANEL ASSEMBLY, GASOGB 20.20 MODELS IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C5115405 PLATE, ELECTRICAL M

Page 26 - C6014003

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2114297 WELDMENT, CONTROL PANEL2 1 C5019101 CONTROLLER, 5010 OPERATING MODULE3 1

Page 27 - 2020 GAS GENERATOR W CLEANING

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 4 100413 FOOT ASS'Y, ADJUSTABLE (FOR 1.250 SQ. TUBING), ANCHORABLE TIEDOWN2 1 C211

Page 29 - 2020 GAS INJ W CLEANING

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C6015215 ELBOW, HOSE CONNECTION, 3/8" WITH SEAL2 2 111647 CLAMP, OETIKER, S/S,

Page 30 - OGB 20.20 MODELS

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 300453 VALVE ASSEMBLY, 3WAY 240VAC1 1 300363 VALVE ASSEMBLY, 3WAY 120 VAC2 5 11149

Page 31

C2016143 A0706IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 300456 VALVE ASSY. 2 WAY 120VAC2 2 111498 HOSE, SILICONE, 3/8" I

Page 32 - ALL MODELS

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 2 C6015401 BARB, 1/2 R X 3/8 HOSE2 1 C5001085 PRESSURE REGULATING VALVE ODGAS3 1 C6

Page 33 - ASSEMBLY, OUTER BASE

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2010050 BURNER INSERT HL, 6.10/6.20, WELDMENT1 C2010052 BURNER INSERT, HL, 10.10/20.1

Page 34

Cleveland STATEMENT OF POLICIES L I M I T E D W A R R A N T Y CLEVELAND RANGE products are warranted to the original purchaser to be free from defec

Page 35

Burner insert 20.20 L.P. C2614863-1 Burner Intake Hose C701210023675

Page 36 - ALL 20.20 MODELS

Burner insert 20.20 Natural Gas C2614863 Burner Intake Hose C701210023675

Page 37

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2616521 BURNER INSERT, HL, PRE-MOUNTED, 6.10/6.201 C2616522 BURNER INSERT, HL, PRE-AS

Page 38 - OGS 20.20 MODELS

Complete Assembly LP: C2314903-1 Burner Intake Hose C701210023675

Page 39 - ALL GAS MODELS

Complete Assembly: C2314903 Burner Intake Hose C701210023675

Page 40 - C2614863-1

CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE.THI

Page 41 - C2614863

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2514363 ASSEMBLY, OUTER DOOR, 20.202 1 C2514394 ASSEMBLY, INNER DOOR, 20.203 1 C

Page 42

IITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2614806 CARRIAGE PLATE, WELDED, 6.20C2614807 CARRIAGE PLATE, WELDED, 10.10 & 10.

Page 43

AEDDEBCINSTALLEDORIENTATIONSECTION E-EDETAIL CDETAIL B DETAIL ASECTION D-D4119 20 81472113 214216182011 211017172214 213 961558 14418C2614801 B, C2614

Page 44 - Complete Assembly: C2314903

54321C3216313 B0706EXTERIOR SHEETINGALL 20.20 MODELSIITTEEMM QQTTYY PPAARRTT NN00.. DDEESSCCRRIIPPTTIIOONN1 1 C2514356 DOOR, 20.20, COMPLETE2 1 C21

Page 45

GENERAL INFORMATION ABOUT COMBIS A. PRODUCT INFORMATION Cleveland Range, LLC assigns two product identification numbers to each Combi: a model numb

Page 46 - 20.20 MODELS

CLEVELAND RANGE OGB 20.20 SEQUENCE OF OPERATIONS When using these instructions refer to the OGB 6.20 wiring schematic. 1 When 120 VAC is applied t

Page 47 - SLIDING PLATE, COMPLETE

• If the condensate box is heated to 140 degrees F at the B3probe, 120 VAC is sent from terminal 5 of connector X12 to the condenser valve (Y1) until

Page 48 - Page 2 of 2

(b) 24 VAC is sent from terminal 2 of connector X2 on the Steam Burner Control Module (N21) to the hot surface igniter (R20). (c) The gas valve is ene

Page 49 - EXTERIOR SHEETING

• A request for heat is sent from terminal 3 of connector X21 on the Gas Board (A20) to terminal 10 on connector X1 on the Steam Burner Control Modul

Page 50 - SEQUENCE OF OPERATIONS

◊ Every 120 seconds the rotation of the motor reverses. ◊ NOTE: If the temperature is less than 212 degrees F than fan will be pulsed on for 2 seco

Page 51

• 120 VAC is sent from terminal 6 of connector X12 on the Control Board (A10) to the Dehumidification Valve (Y2) to pull the humidity out of the cabi

Page 52

• When the heat circuit is energized the heat symbol will be energized • The cooking mode symbol will be energized. • The time display will invert

Page 53

CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574VOLTAGE: WATTAGE: CURRENT: DATESHEET OF REVDRAWN BYDRAWING NO.THIS DESIGN DE

Page 54 - Hot Air heat

C-M2TW/GYTW/GYV2/WHU2/RDW2/YEM 3~SHGND-X13.4-X13.3BK 18BK 18BK 18-A10:X15:9-A10:X15:10-A10:X15:11V1/BUFANW1/BNU1/BKRPM-BM1.1BKRDBN912379217388-X13.521

Page 55

BU 18-A1312BK 18WH 1834RD 18D4-A10:X10:12-A10:X10:11D4-A10:X10:10D4-A10:X10:9D4IDENTIFICATION MODULE-B5PROBE BYPASS103BU 18-M3.2-M3.1COOLING FANS-H5.2

Page 56

INSTALLATION INSTRUCTIONS A. GENERAL This equipment should be installed only by qualified, professional plumbers, pipe fitters, and electricians. 1

Page 57 - CLEVELAND RANGE, LLC

-U20:X2:3-U20:X2:4-U20:X2:2/5.C6-U21:X2:3-U21:X2:4-U21:X2:2/6.C6X27:81211109-A203765421HEAT REQUEST310 912 11 36548712345678GAS BOARDGM5010X26:RECIEVE

Page 58 - WIRING DIAGRAM

BU 18RD 18BU 18RD 18GN 18RD 18BU 18 22 21OVER TEMPERATURE THERMOSTAT-B7.1/6.A1N/3.F7N-X1022/3.D5-X10:33/6.A4-X10:35-X1034RD 18(HOT AIR)RD 18BU 1878-K

Page 59

BU 18RD 18BU 18RD 18GN 18RD 18BU 18/7.A1N/5.A8N-X1024/5.A5-X10:34/7.B2-T3:BK-X1035RD 18GNDGN 18-U21POWER BURNER STEAM GENX1: X2:X3:X1:X2:123 123451234

Page 60

X3:BURNER (HOT AIR)-T3RD 16RD 16BK 16BU 16WH 16OR 1624 VAC120VAC -X10:24/6.A8BU 18RD 18NGN 18GND-X10104BU 18BU 18BU 18-N22213-A20:X25:12-X10:46/4.B3/4

Page 61

24 VAC120VAC -T1120VAC -T2RECIEVETRANSMIT12VGND6875MOTOR DRIVE2ARD-Z1L1NNL1FANGNDRxD12VCOMTxDV2/WHW2/YEU2/RD-U10.2SHGNDM 3~CONVECTIONV1/BUU1/BKW1/BN-M

Page 63

L1- 110/120 VAC-INPUTCONDENSOR/VALVEGEM FILL/VALVESTEAM GEN PUMPPUMP / RINSEDEHUMIDICATION/VALVESTEAM GEN OVER TEMPCOMPARTMENT RINSE V.PUMP / CLEAN

Page 64 - LADDER DIAGRAM

CLEVELAND RANGE OGS 20.20 SEQUENCE OF OPERATIONS When using these instructions refer to the OGS 20.20 wiring schematic. 1 When 120 VAC is applied

Page 65

a The front display will include a lighted bar under the steam symbol • When the heat circuit is energized the heat symbol will be energized • The

Page 66

5 With the combi in the Hot Air mode with time on the timer, the door closed and the start switch is depressed a The front display will include a li

Page 67 - CLEVELAND RANGE OGS 20.20

. INSTALLATION OF THE COMBI – General Instructions General Instructions: 1. Select the Combi’s operating location. 2. Complete the water, drain, a

Page 68

◊ In the full mode (3 drops in the display) the Y2 valve will be energized continuously. f When the timer counts to 0 or the core temp probe (B10) r

Page 69

• If the bypass probe (B5) drops below the set level the steam circuit will start again. e When the condensate box is heated to 140 degrees F at the

Page 70

◊ The gas valve is energized allowing gas and air into the burner chamber to be ignited by the hot surface igniter. ◊ The Hot Air Burner Control Mod

Page 71

CLEVELAND RANGE, LLC1333 East 179th St., Cleveland, Ohio 44110-2574VOLTAGE: WATTAGE: CURRENT: DATESHEET OF REVDRAWN BYDRAWING NO.THIS DESIGN DE

Page 72

C-M2TW/GYTW/GYV2/WHU2/RDW2/YEM 3~SHGND-X13.4-X13.3BK 18BK 18BK 18-A10:X15:9-A10:X15:10-A10:X15:11V1/BUFANW1/BNU1/BKRPM-BM1.1BKRDBN912379217388-X13.521

Page 73

BU 18-A1312BK 18WH 1834RD 18D5-A10:X10:12-A10:X10:11D4-A10:X10:10D4-A10:X10:9D4IDENTIFICATION MODULE-B5PROBE BYPASS103BU 18-M3.2-M3.1COOLING FANS-H5.2

Page 74

-U20:X2:3-U20:X2:4-U20:X2:2/5.C6X27:81211109-A203765421HEAT REQUEST310 912 11 36548712345678GAS BOARDGM5010X26:RECIEVETRANSMIT12VGND12VDC IN0VDC INRxD

Page 75 - CLEANING OPTION ONLY

BU 18RD 18BU 18RD 18GN 18RD 18BU 18 22 21OVER TEMPERATURE THERMOSTAT-B7.1/3.F7N-X1022/3.D5-X10:33-X1034RD 18(HOT AIR)RD 18BU 1878-K06543B4/7.B4GNDGN

Page 76

X3:BURNER (HOT AIR)-T3RD 16RD 16BK 16BU 16WH 16OR 1624 VAC120VAC -X10:24/5.A8BU 18RD 18NGN 18GND-X10104BU 18BU 18BU 18-N22213-A20:X25:12-X10:46/4.B3/4

Page 77

24 VAC120VAC -T1RECIEVETRANSMIT12VGND6875MOTOR DRIVE2ARD-Z1L1NNL1FANGNDRxD12VCOMTxDV2/WHW2/YEU2/RD-U10.2SHGNDM 3~CONVECTIONV1/BUU1/BKW1/BN-M2-A20:X250

Page 78

C. SPECIAL INSTRUCTIONS FOR CASTER EQUIPPED COMBI STANDS AND COMBIS 1. Read all instructions before beginning installation. 2. Level the floor if

Page 79

FLAMECHECKNEUTRALHI- LIMITRESET AIR HEAT/GOPHASE ( L1 )RESET AIR HEATGND12 10 911 687X1:2154 3HOT SURFACE -N20CONTROL MODULE HOT AIR213X2:GASVALV

Page 80

L1- 110/120 VAC-INPUTCONDENSOR/VALVEGEM FILL/VALVESTEAM GEN PUMPPUMP / RINSEDEHUMIDICATION/VALVESTEAM GEN OVER TEMPCOMPARTMENT RINSE V.PUMP / CLEAN

Page 81

1333 East 179th St., Cleveland, Ohio, U.S.A. 44110Ph: 1-216-481-4900 Fx: 1-216-481-3782 Web Site: www.clevelandrange.comCleveland Range, LLCS